Experimental Research 2025.Vol No.20

Citation:DOI: 10.7672 / sgjs2025200160

Mechanical Performance Research of Full-bolted Connection Plate Joints for Steel Truss

HUANG Weizhen1, DUAN Xianjun2, WANG Shuguang2, ZHANG Guojun1,LI Jiguang2, LIU Xingang1, LUO Baolin2

About the author:

1. China Aviation Planning and Design Institute (Group) Co., Ltd., Beijing 100120,China;2. Beijing Urban Construction Group Co., Ltd., Beijing 100088, China

Abstract:

The inclined web components of the large-span steel trusses in the roof of a large overseasterminal building adopt on-site connection plate joints with fully high-strength bolts. Through comparativeexperimental studies, the original design of the joints was verified to be safe and reliable in terms ofmechanical performance. Within the scope permitted by the code, the bolt group distribution of theoriginal design was optimized, and the test results showed that the bearing capacity of the optimizedconnection plate joints increased by 24.4%. Based on the experimental research, numerical analysis wasconducted on connection plate joints with different plate thicknesses and bolt group distributions. Theresults indicated that increasing the thickness of the insert plate could enhance the stability and bearingcapacity of the connection zone. By analyzing the stress transfer mechanism of the connection plates, amodified calculation method for connection plate stress applicable to this type of joint was proposed.